PerfectDry Lux

PerfectDry Lux

Rp 0,00
Sale price  Rp 0,00 Regular price 
Skip to product information
PerfectDry Lux
1/6
Products chevron_right Electronic Medical Devices chevron_right PerfectDry Lux
Medical Device · FDA (QSR/GMP) · IEC 60601 · FCC · CE MARKED (EU MDR)

PerfectDry Lux

The PerfectDry Lux is a Medical Device for the maintenance and storage of all kind of hearing aids. Its modern and sleek design combined with the best technology makes it exceptionally convenient to use. Its efficiency in dehumidifying in only 45 minutes has been proved by many tests.

timerFull 45-min cycle — dehumidification efficiency proved by many tests thermostatMax temperature 35°C / 95°F — self-regulated by microprocessor regardless of ambient temperature, safe for all hearing aids wb_sunnyUV-C lamp 360° · 253.7nm · 2W — annular peripheral light reaching all hearing aid surfaces, automatic shutdown when cover is opened boltPower supply 5Vdc · 4W max · standby < 0.02W — certified universal adapter 100–247Vac, compliant with electrical safety and EMC requirements scale160g · dimensions 93 × 48 × 76 mm (ext.) — internal cavity 70 × 21 × 51 mm, modern and compact design devicesCompatible with all brands and models — tested with no damage to nano-coating, varnishes and rechargeable models
gavel
FDA
QSR / GMP
electrical_services
IEC 60601
Electrical safety
wifi
FCC
Wireless / electromagnetic compliance
health_and_safety
CE MARKED (EU MDR)
Medical Device
science
Intertek Certified
UV-C efficacy validated
power
100–247 Vac
Universal adapter

Professional pricing on request. Volume orders, customizable packaging, worldwide delivery.

Functions & technologies

Four integrated technologies
for optimal maintenance

The PerfectDry Lux incorporates a control microprocessor that simultaneously manages all onboard technologies — for maximum performance at every cycle.

schema Integrated functions diagram
PerfectDry Lux — Functions diagram
air
Patented system

Pulsed hot air dehumidification

The patented pulsed hot air system reduces power consumption and dehumidification times. Temperature is self-regulated by the microprocessor to never exceed 35°C / 95°F, regardless of ambient temperature.

thermostatMax temperature: 35°C / 95°F — microprocessor self-regulation
wind_powerControlled ventilation — optimized and homogeneous airflow
waterActive moisture extraction proven by testing
verifiedPatented
wb_sunny
Intertek certified

360° UV-C lamp — Optimal hygiene

The UV-C shortwave lamp (253.7nm) and its 360° annular arrangement allow every surface of the hearing aid to be reached. System efficacy is certified by internationally recognized laboratory Intertek, in accordance with UV-C requirements for the medical field.

radio_button_checked253.7nm — short wavelengths
360360° — peripheral light (2 Watts)
shieldTested with no damage to hearing aid surfaces (nano-coating, varnishes)
power_settings_newAutomatic shutdown when the cover is opened
scienceIntertek — Medical UV-C requirements
memory
Intelligent control

Microprocessor control

A microprocessor simultaneously manages the dehumidification system and the UV-C system, ensuring optimal coordination of both technologies throughout the full 45-minute cycle.

tuneSimultaneous control — dehumidification + UV-C
sensorsLid opening sensor — automatic cycle stop
power_settings_newAutomatic shutdown at end of cycle — standby power <0.02W
boltStandby < 0.02W
touch_app
Ease of use

One Touch control

A single curved sensor touch button to start, monitor and stop the cycle. Clean and modern design conceived for intuitive use by all audiences.

touch_appCurved sensor touch button — cycle launch in one gesture
design_servicesModern and elegant design — suitable for all users
timer45-min cycle · automatic stop at end of maintenance
timer45 min per cycle
PerfectDry Lux — Drying test chart
Properties & directions for use

Quick and effective cleaning
anywhere and at any time

The cleaning wipe solution is specially designed to effectively dissolve earwax without damaging hearing aids. Convenient and hygienic, individually packaged wipes are ideal for daily maintenance at home or on the go.

info

Directions for use

1

Open the bag

Open the individual bag and remove the wipe.

2

Clean

Clean hearing aids or earmolds with the wipe.

3

Wipe dry

Wipe the hearing aid with a soft, dry cloth.

calendar_todayDaily cleaning of hearing aids and earmolds is recommended
cachedSingle use — discard the cleaning wipe after use
warning

Precautionary statements

child_careKeep out of reach of children
local_pharmacyExternal use only
cachedSingle use — do not reuse the wipe
biotech Composition
check_circleWater
check_circleAlcohol
check_circleCaprylyl Glycol
check_circleEthylhexylglycerin
check_circleBenzalkonium Chloride
verified_user

  • Our products are developed and manufactured in compliance with applicable U.S. Food and Drug Administration (FDA) requirements.
  • Manufactured under a quality management system compliant with FDA Quality System Regulation (21 CFR Part 820).
  • Manufactured in accordance with Good Manufacturing Practices (GMP).
  • CE marked (EU MDR), confirming adherence to European regulations governing medical device safety and quality.

Technical specifications

Electrical & mechanical characteristics

bolt

Electrical specifications

Device power supply5 Vdc
Max power4 W
Standby power< 0.02 W
Adapter — Input100–247 Vac · 50–60Hz
Adapter — Output5 Vdc
AdapterUniversal
Adapter certificationEMC & safety compliant
straighten

Mechanical specifications

External dimensions (W × H × D)93 × 48 × 76 mm
Internal dimensions (W × H × D)70 × 21 × 51 mm
Weight160 g
Cycle duration45 min
Max temperature during cycle35°C / 95°F
UV-C253.7 nm · 2W · 360°
CompatibilityAll brands

square_footUnit dimensions

PerfectDry Lux — Unit dimensions
Indications & regulatory compliance

Medical properties & applicable directives

medical_services

Medical indications

water_damageDehumidification of hearing aids to prevent dysfunction due to humidity
wb_sunnyTreatment of hearing aid surfaces to limit ear canal pathologies associated with wearing
trending_upRegular use increases the lifetime of the hearing system and preserves their effectiveness
info

Usage precautions

Clean hearing aids before the cycle. If possible, open the battery compartment to enable full dehumidification.
child_careKeep out of reach of children
constructionAny intervention other than routine cleaning must be performed by the manufacturer's after-sales service or an authorized professional service
power_offDo not immerse the unit, cord or plug in water or any other liquid
gavel

Regulatory compliance, standards and certifications

check_circle
FDAOur products are developed and manufactured in compliance with applicable U.S. Food and Drug Administration (FDA) requirements.
check_circle
FDA · 21 CFR Part 820Manufactured under a quality management system compliant with FDA Quality System Regulation (21 CFR Part 820).
check_circle
GMPManufactured in accordance with Good Manufacturing Practices (GMP).
check_circle
FCC & IEC 60601Our product complies with FCC requirements for electromagnetic compatibility in the United States and meets IEC 60601 standards, ensuring electrical safety and performance for medical devices.
check_circle
CE MARKED (EU MDR)Class I Medical Device — compliant
check_circle
Intertek CertifiedUV-C efficacy validated by accredited laboratory
Professional orders

Customization, volume & quote

The PerfectDry Lux is available for professional ordering with fully customizable packaging. Pricing on request based on volume and specifications.

branding_watermark

White-label & custom packaging

Full adaptation to the partner's brand identity — colors, logo, local-language instructions, regulatory compliance.

inventory

Volume orders

Volume-based pricing. Integrated stock and supply management. Delivery to 40+ countries with customs management.

science

Samples available

Samples can be provided on request before any series order, for technical and commercial validation.

Request a PerfectDry Lux quote

Indicate the estimated volume, target market and any customization specifications. The MG Development sales team responds within 48h.

scheduleResponse within 48h
local_shippingWorldwide delivery — customs included
verified_userGuaranteed regulatory compliance
request_quoteRequest a Quote scienceRequest a sample

No prices displayed — pricing on request only